1.3 Specifications

1.3.1 General Description

Control Bus
Original bus (16-bit, 24 MHz)
Switching
Space Division CMOS Crosspoint Switch
Power Input
100 V AC to 240 V AC, 1.5A to 0.75A, 50 Hz/60 Hz
External Battery
+24 V DC (+12 V DC × 2)
Maximum Power Failure Tolerance
300 ms (without using backup batteries)
Memory Backup Duration
7 years
Dialling
Outside (CO) Line
Pulse (10 pps, 20 pps) or Tone (DTMF)
Extension
Pulse (10 pps, 20 pps) or Tone (DTMF)
Intercom Path
4
Mode Conversion
Pulse-DTMF
Ring Frequency
20 Hz/25 Hz (selectable)
Operating Environment
Temperature
0 deg.gif to 40 deg.gif
Humidity
10 % to 90 % (non-condensing)
Conference Call Outside (CO) Line
2
Music on Hold (MOH)
1 port
Selectable MOH: Internal/External/Tone
Paging
Internal
1
External
1 port
Serial Interface Port
RS-232C
1
USB 1.1
1
Extension Connection Cable
SLT
1-pair wire (T, R)
PT
2-pair wire (T, R, H, L)
DSS Console
1-pair wire (H, L)
Dimensions
368 mm (W) × 284 mm (H) × 102 mm (D)
Weight (when fully expanded)
Approx. 3.5 kg

1.3.2 Characteristics

Terminal Equipment Loop Limit
PT
40 W
SLT
600 W including set
Doorphone
20 W
Minimum Leakage Resistance
15 000 W minimum
Maximum Number of Extension Instruments per Line
1 PT or SLT in standard connection
1 PT and 1 SLT in parallel connection
Ring Voltage
75 Vrms at 20 Hz/25 Hz depending on the ringing load
Outside (CO) Line Loop Limit
1600 W maximum
Hookswitch Flash/Recall Timing Range
24 ms–2032 ms
Door Opener Current Limit
30 V DC/125 V AC, 3 A maximum
Paging Terminal Impedance
600 W
MOH Terminal Impedance
10 000 W

1.3.3 System Capacity

System Capacity

  

TES824

TEM824

Basic System
Outside (CO) lines
3
6
Extensions
8
16
Fully Expanded System
Outside (CO) lines
8
8
Extensions
24
24

Maximum Cards and Terminal Equipment

Item

TES824

TEM824

PT and SLT
40
40
3-Port Analogue CO Line and 8-Port Hybrid Extension Card
1
2-Port Analogue CO Line and 8-Port SLT Extension Card
1
1
8-Port SLT Extension Card
1
1
Message Expansion Card for DISA/UCD OGMs
1
1
4-Port Doorphone Card
1
1
3-Port Caller ID Card
3
3
2-Channel Voice Message Card
1
1
Doorphone
4
4
Door Opener
4
4
Pager
1
1
Music on Hold (MOH)
1
1
DSS Console
2
2

System Data

Item

Max. Quantity

Operator
1
System Speed Dialling
100
One-touch Dialling
24 per extension (PT)
Personal Speed Dialling
10 per extension
Call Park Area
10
Absent Message
6
Toll Restriction (TRS) COS
5
Extension Group
8
Message Waiting
8 per extension
Message for Built-in Voice Message
125 messages (total 60 minutes)